JINSP
ST830E
OCT
Spectrometer
Imaging
Spectrometer
with
Customized
Wavelength
Range
Product
Specifications
Attribute
|
Value
|
Photosensitive
area
|
20.52*0.2mm
|
Cell
size
|
10*200um
|
Wavelength
range
|
Customized
in
the
range
of
790-930nm
|
Optical
resolution
|
0.07nm
|
Imaging
depth
|
2.4mm
|
Effective
Pixels
|
2048
|
Product
Description
The
ST830E
series
spectrometer
achieves
wavenumber
linear
spatial
dispersion
through
specialized
optical
path
design,
enabling
equal
interval
sampling
of
wavenumber
at
the
hardware
level.
This
allows
for
direct
FFT
processing
of
acquired
interference
spectra
without
requiring
wavenumber
resampling
algorithms,
significantly
reducing
data
processing
complexity
while
improving
system
signal-to-noise
ratio.
Detector
|
Line
array
CMOS
|
Effective
pixels
|
2048
|
Cell
size
|
10*200um
|
Photosensitive
area
|
20.52*0.2mm
|
Wavelength
range
|
Customized
in
the
range
of
790-930nm
|
Optical
resolution
|
0.07nm
|
Optical
design
|
VPH
raster
&
wave
ridge
linear
design
|
Maximum
line
sweep
speed
|
130kHz/250kHz
|
Incident
optical
interface
|
FC/APC
fibre
optic
interface
|
Technical
Highlights
-
Special
optical
path
design
enables
hardware-level
equal
interval
sampling
of
wavenumber
-
Direct
FFT
processing
of
interference
spectra
eliminates
need
for
wavenumber
resampling
algorithms,
reducing
data
processing
complexity
and
improving
signal-to-noise
ratio
-
High-efficiency
VPH
gratings
with
near-diffraction-limited
optical
resolution
-
Industry-leading
line
scan
rate
of
up
to
250kHz
Applications
The
OCT
spectrometer
is
a
critical
component
of
optical
coherence
tomography
(OCT)
systems,
providing
non-invasive
imaging
of
internal
biological
tissue
structures.
The
ST830E
model's
250kHz
line
scan
rate
and
10*200um
cell
size
make
it
ideal
for
high-speed,
high-resolution
imaging
applications.
Featuring
direct
FFT
processing
without
wavenumber
resampling
algorithms,
this
spectrometer
delivers
superior
image
quality.
Its
high-efficiency
VPH
gratings
with
near-diffraction-limited
resolution
make
it
suitable
for
demanding
applications
in
ophthalmology,
dermatology,
and
cardiology.
Frequently
Asked
Questions
What
is
the
brand
name
of
the
OCT
Spectrometer?
The
brand
name
is
JINSP.
What
is
the
model
number
of
the
OCT
Spectrometer?
The
model
number
is
ST830E.
Where
is
the
OCT
Spectrometer
manufactured?
The
spectrometer
is
manufactured
in
China.
What
are
the
payment
terms
for
purchasing
the
OCT
Spectrometer?
Payment
terms
include
T/T
and
Western
Union.